Produkt-Details
Herkunftsort: Shanghai, China
Markenname: TANKII
Zertifizierung: ISO9001
Modellnummer: PtIr 90/10
Zahlungs-u. Verschiffen-Ausdrücke
Min Bestellmenge: 200 Stk
Preis: Verhandlungsfähig
Verpackung Informationen: Holzkiste
Lieferzeit: 7-20 Tage
Zahlungsbedingungen: L/C, T/T, Western Union
Versorgungsmaterial-Fähigkeit: 10 Tonnen pro Monat
Material: |
PtIr 90/10 |
Aus Diamater: |
0.2mm Min. |
Probe: |
kleiner Auftrag angenommen |
Länge: |
0.2mm Min. |
HS-Code: |
7115909000 |
Oberfläche: |
Blankgeglüht |
Material: |
PtIr 90/10 |
Aus Diamater: |
0.2mm Min. |
Probe: |
kleiner Auftrag angenommen |
Länge: |
0.2mm Min. |
HS-Code: |
7115909000 |
Oberfläche: |
Blankgeglüht |
pt-Ir alloy good stability stable biocompatibility ,high density, suitable for development applications
Developing ring is an optical accessory used in microscope observation, mainly used phase contrast or interference contrast technology, by adjusting the phase or interference of light so that different parts of the sample produce different contrast, thereby highlighting the details of fine structure. Developing rings play an important role in electron microscopy, helping to enhance the contrast and clarity of the sample, making the microstructure more clearly visible.
Application of developing ring in medical field
Medical development rings are medical devices used to provide accurate images of organs in the body to help doctors in disease diagnosis and treatment planning. The working principle of the developing ring is based on advanced imaging technology, which provides high-resolution images so that doctors can see the lesion clearly
Platinum-iridium alloy is one of the most stable alloy materials with chemical, mechanical and electrical properties, and has the characteristics of high strength, high elasticity, low contact resistance, etc., which is in line with human biocompatibility. Medical industry with high precision developing ring, high-temperature alloy ring, tolerance up to micron level, because the product is very small, high precision.
Pt90lr10.
| OD mm |
W.T. /mm | |||||||||||||
| ≥0.015 | ≥0.02 | ≥0.05 | ≥0.10 | ≥0.20 | ≥0.30 | ≥0.40 | ≥0.50 | ≥0.60 | ≥0.70 | ≥0.80 | ≥0.90 | ≥1.00 | ≥1.5 | |
| ≥0.3 | - | - | - | |||||||||||
| ≥0.5 | - | - | - | - | - | |||||||||
| ≥1.0 | - | - | - | - | - | - | - | |||||||
| ≥1.5 | - | - | - | - | - | - | - | - | - | |||||
| ≥2.0 | - | - | - | - | - | - | - | - | - | |||||
| ≥3.0 | - | - | - | - | - | - | - | - | - | - | ||||
| ≥4.0 | - | - | - | - | - | - | - | - | - | - | - | |||
| ≥5.0 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ≥6.0 | - | - | - | - | - | - | - | - | - | - | - | - | - | |
| ≥7.0 | - | - | - | - | - | - | - | - | - | - | - | - | - | |
| ≥8.0 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| ≥9.0 | - | - | - | - | - | - | - | - | - | - | - | |||
| ≥10.0 | - | - | - | - | - | - | - | - | - | - | ||||
| ≥15.0 | - | - | - | - | - | - | - | - | - | |||||
| ≥20.0 | - | - | - | - | - | - | - | - | ||||||
| Material | Melting point (ºC) | Density (G/cm3) | Vickers hardnes Soft |
Vickers hardnes Hard |
Tensile force (MPa) |
Resistivity (uΩ.cm)20ºC |
| Platinum (99.99%) | 1772 | 21.45 | 40 | 100 | 147 | 10.8 |
| Pt-Rh5% | 1830 | 20.7 | 70 | 160 | 225 | 17.5 |
| Pt-Rh10% | 1860 | 19.8 | 90 | 190 | 274 | 19.2 |
| Pt-Rh20% | 1905 | 18.8 | 100 | 220 | 480 | 20.8 |
| Platinum-Ir (99.99%) | 2410 | 22.42 | ||||
| Pure Platinum-Pt (99.99%) | 1772 | 21.45 | ||||
| Pt-Ir5% | 1790 | 21.49 | 90 | 140 | 174 | 19 |
| Pt-lr10% | 1800 | 21.53 | 130 | 230 | 382 | 24.5 |
| Pt-Ir20% | 1840 | 21.81 | 200 | 300 | 539 | 32 |
| Pt-lr25% | 1840 | 21.7 | 200 | 300 | 238 | 33 |
| Pt-Ir30% | 1860 | 22.15 | 210 | 300 | 242 | 32.5 |
| Pt-Ni10% | 1580 | 18.8 | 150 | 320 | 441 | 32 |
| Pt-Ni20% | 1450 | 16.73 | 220 | 400 | 588 | 34.1 |
| Pt-w% | 1850 | 21.3 | 200 | 360 | 588 | 62 |
| Applications: Gas sensors. Various sensors, medical components. Electric and heating probes, etc. | ||||||